Experiment manifest (schema version 1.0)

A manifest declares which data file to read, its format, experiment identity, and optional instrument/sample/default metadata. JSON is canonical; YAML is accepted as an authoring convenience. The machine-readable schema is schemas/generic-manifest-v1.schema.json, kept consistent with the Pydantic model by a test.

Minimal example

{
  "schema_version": "1.0",
  "format": "generic-long",
  "data_file": "scans.csv",
  "experiment": {
    "experiment_id": "synthetic-001",
    "name": "Synthetic absorbance run",
    "experiment_type": "sedimentation_velocity"
  },
  "defaults": {
    "optical_system": "absorbance",
    "signal_unit": "absorbance_unit",
    "cell": "1",
    "channel": "A"
  }
}

Top-level fields

Field Required Notes
schema_version yes Must be "1.0". Any other value is a ManifestError.
data_file yes Relative path to the data file. Absolute paths and paths escaping the experiment directory (.., drive letters) are rejected.
experiment yes Contains at least experiment_id.
format no "generic-long" or "generic-wide". If omitted, the parser is chosen by detection.
instrument no Optional instrument/run metadata.
samples no Optional list of sample metadata.
defaults no Scan-level defaults (see below).
columns no Required for wide format (see below).
delimiter no ",", "\t", "comma" or "tab" — an explicit override.
notes no Free text, retained.
extension no A documented escape hatch object for forward-compatible extra data.

Unknown top-level fields are rejected (extra="forbid"), except the documented extension object.

Defaults and conflicts

defaults supplies scan metadata where the table does not. A default that conflicts with a value supplied in the table is an error (DataConflictError), never a silent override.

Missing vs unknown

Absent optional fields stay absent (None); the model does not invent values. Where the canonical model distinguishes present / missing / unknown / not-applicable, that distinction is preserved (for example, a scan with no elapsed_seconds gets an explicitly missing elapsed time). See missing and unknown values.

Wide-format columns

"columns": {
  "radius": "radius_cm",
  "scans": [
    {"column": "scan_001", "scan_id": "scan_001", "elapsed_seconds": 0},
    {"column": "scan_002", "scan_id": "scan_002", "elapsed_seconds": 600}
  ]
}

Each entry maps a signal column to a scan id and optional per-scan metadata (elapsed_seconds, wavelength_nm, optical_system, rotor_speed_rpm, temperature_c, cell, channel, source_scan_id).

Instrument and sample metadata

Instrument and sample fields use author-friendly, unit-suffixed scalars (nominal_speed_rpm, temperature_c, wavelength_nm, concentration_value with concentration_unit, …). The parser converts these into canonical Quantity values with their declared units; it never infers a unit from a value.